Here is the instruction show you guide on how to perform relief valve setting pressure for Kubota L3301 L3901.
Related Contents:
[06.2025] Kubota DiagMaster 25.02.01 Level 9 Takechi,Manitou,Carrier,Nonself
[06.2021]Kubota EPC PAD KDG+LinkOne EPC 2003 2 in 1 VMware
Genuine Kubota DST-i Diagnostic Adapter
Relief Valve Setting Pressure
1 Disconnect the power steering delivery pipe joint bolt.
2 Install the adaptor E instead of joint bolt, and then set a thread joint, cable and pressure gauge.
3 Start the engine and set the engine speed at max. speed.

4 Fully turn the steering wheel to the left or right and read the pressure when the relief valve functions.
5 Stop the engine.
6 If the pressure is not within the factory specifications, check the pump delivery line, and adjust relief valve setting pressure by turning adjusting screw (1).