This instruction show you guide on how to solve Deutz trouble code 83/975/FanCD FAN actuator error.
Fan power stage: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the ECU component for power supply of the actuator is exceeded

Related Contents:
Error codes
DEUTZ-Errorcode: 83
BlinkCode (short-long-short): 2 – 3 – 8
SPN: 975
possible FMI:
3: Voltage to high or short circuit to +Ubatt
4: Voltage to low or short circuit to -Ubatt
5: current to low or broken wire
2: data stream is defective
Error detection
Errorlamp shows permanent light. Entry in errormemory.
Possible reason for error
cable break or short circuit, sensor defective, connection cable damaged
Take actions for error repair
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it other error properties
System reaction: Warning, shutoff output
Behaviour error lamp: permanent light
Selfhealing: no
Signal Priority: 2