How to Solve Deutz 83/975/FanCD FAN Actuator Error

This instruction show you guide on how to solve Deutz trouble code 83/975/FanCD FAN actuator error.

Fan power stage: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the  ECU component for power supply of the actuator is exceeded

Deutz EMR3 engine control unit ArHt1.

Related Contents:

Deutz Serdia 4.0

Deutz DECOM

 

Error codes

DEUTZ-Errorcode: 83

BlinkCode (short-long-short): 2 – 3 – 8

SPN: 975

 

possible FMI:

3: Voltage to high or short circuit to +Ubatt

4: Voltage to low or short circuit to -Ubatt

5: current to low or broken wire

2: data stream is defective

 

Error detection

Errorlamp shows permanent light. Entry in errormemory.

 

Possible reason for error

cable break or short circuit, sensor defective, connection cable damaged

 

Take actions for error repair

Check cabling, sensor defect, check sensor and if necessary  replace it, check connection cable and if necessary repair or replace it other error properties

 

System reaction: Warning, shutoff output

Behaviour error lamp: permanent light

 

Selfhealing: no

Signal Priority: 2