This instruction show you guide on how to solve Doosan Bobcat fault code P203A DEF level sensor open circuit.

 

Preparations:

2026 Doosan Data Monitoring System DMS-5

2025 Doosan Diagnostic Software Full Package

Doosan uVIM Diagnostic Tool

 

 

1 Overview

E SPNFMI:E00353203

 

Reason:

1 Electrical problem (DEF level sensor, Wiring harness in the DEF module)

2 Electrical problem (CAN wiring harness-insulation,Resistance)

 

Effect:Inducement Group5 (Tampering)

 

The pin definition is dependent on the DEF tank type.

No Description

1 Battery +12V

2 Ground

3 CAN Low

4 CAN High

 

2) Component Location

DEF tank location and connector is dependent on machine application.

How to Solve Doosan Bobcat Fault Code P203A DEF Level Sensor Open Circuit (1)

3) Condition for Running Diagnostic

Continuously checked in every sample time when there is no bus-off and no timeout error

 

4 Condition for Setting the Fault Code

The error is reported if its FMI is equal to 3 (Open circuit)

 

5 Condition for Clearing the Fault Code

The error is healed when its FMI is not equal to 3

 