Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service Error Solution

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (8)

This instruction show you guide on how to solve Liebherr machine engine D966 D9512 ECU2 ECU2-HD ECU3 trouble code P1120 scr system (air pump/air supply valve) out of service.

 

Related Contents:

Liebherr LIDIA 2026 Diagnostic Software

Liebherr Diagnostic Kit

 

Reason:

The failure code is displayed during check phase :

  • Air supply is always ON (No air supply stop in Sensor Check phase)
  • Air supply is always OFF (No air supply in PreCheck 1/2/3 phase)

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (1)

 

Troubleshooting

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (2) Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (3)

 

 

Consequence:

  • As the P1120-00 failure is emission relevant, the inducement process starting with P1187-00 “Inducement system – Warning (SCR failure) will begin, leading to a power reduction if the failure is not solved.
  • If a second occurrence of the failure comes back, this leads to a repeated offense issue which means that the engine will stay blocked in the latest stage of inducement. As a consequence, Service Technician is needed to remove the power reduction.

 

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (4)

 

Component Location:

EATS All versions

D956-D966 A7-04 (SCR only)

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (5)

 

D956-D966 A7-05 StageV (SCR Filter)

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (6) Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (7)

 

 

D9512 A7 04-05-StageV

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (8)

Primary (A700)

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (9)

Secondary (A760)

Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (10) Liebherr ECU2 ECU2-HD ECU3 P1120 SCR System Out of Service (11)