This instruction show you guide on how to solve JCB 140 205 excavator C0393-13 swing lock solenoid open circuit error.
Preparations:
2025 JCB ServiceMaster 4 v25.1.0
2017 JCB Parts Plus+ and Repair Service Manual
Possible Cause:
1 Swing solenoid not connected to machine wire harness.
2 Faulty Solenoid.
3 Terminal back out on the MECU wire harness connector.
Diagnosis:
1 Check the wire harness connection on swing solenoid. Refer below photograph.
2 Check the solenoid coil circuit resistance. The resistance of solenoid coil shall be 37Ω.
3 Check the circuit no 8049 on cavity no 56 & circuit no 4049 on cavity no 25 in the MECU wire harness connector in CAB base harness for terminal back out. Refer the below photograph.