Description
AGCO Electronic Diagnostic Tool EDT is a set of programs that allows (using the appropriate adapter, which is purchased separately) to diagnose via the CAN data bus of AGCO Inc. products, which also provides an interpretation of error codes,which includes (not for all products) electrical circuits, description of sensors and locations their installation as well as solving the most common problems in the electrical field.
Note:After payment you will get download link on page,if you can not get it,please send email to autoepccatalog@outlook.com
AGCO EDT Electronic Diagnostic Tool Features:
Released Date:2025.09/2025.04
Date version:1.128.24284.909
Size:install files about 38GB
License:5 years
OS:Windows 10 and Windows 11 recommended
Offline version,it can not do online functions
Support 60%-70% models,it can not support all models
Languages:English,Dutch,French,Finnish,German,Spanish,Portugese,Danish,Russian,Polish,Italian,Turkish,Swedish,Chinese,Norwegian.
Regions:South America,North America,Western Europe,Eastern Europe,Africa/Middle East,Asia, Australia/New Zealand/Japan.
Price only for ONE PC installation,my tech team will install it for you by remote.
it will take long time to finish installation,3-6 hours
It is important to emphasize that the AGCO EDT OFFLINE versions, despite the fact that all brands are displayed, not all of them are properly activated with their plugins.
It is also important to emphasize that for the FENDIAS brand the FENDT FENDIAS program is necessary, for them a DONGLE is also needed. This is relevant as FENDIAS in AGCO EDT is just a redirector to FENDT FENDIAS.
AGCO EDT Electronic Diagnostic Tool Functions:
Network Scan
Diagnostic by Function
Calibration
Configuration
Diagnostic Test
Software Flash
Diagnostic Trouble Codes
Diagnostic Fault Trees
Engine Sensors Overview
CAN Trace
Calibrations:
– Main Gear Calibration (Versu / Direct / Hitech 5PS)
– Range Gear Calibration (Versu / Direct / Hitech 5PS)
– Hydrostatic Unit (Direct only)
– Speed Sensor Calibration
– F- clutch Calibration
– R-clutch Calibration
– C1-clutch Calibration (Versu / Hitech)
– C2-clutch Calibration (Versu / Hitech)
– C3-clutch Calibration (Versu / Hitech)
– C4-clutch Calibration (Versu / Hitech 5PS)
– Clutch Pedal Calibration
– Powershuttle Adjustments
– Powershift Adjustments (Versu / Hitech)
– Injector Calibration
Configuration
– Save TC1 indexes to EDT
– Load TC1 indexes to EDT
– Update TC1 indexes with latest factory values
– Adjust TC1 indexes
– Adjust Tractor Terminal Indexes
– Reset Tractor Terminal User Settings
– Change the identifier (CAN ID)
– Hydraulic Configuration
– Tractor number
– Valve head management
– VIN Setup
– Cooling Fan Setup
– Engine Service Parameter Configuration
– Use Engine Activation Code
– Bypass Specification Mismatch
Diagnostic Test
– Hydrostatic Unit Test (Direct only)
– Visco Fan Test
– Cylinder Cut-Out Test
– High Pressure Test
– Run-Up Test
– Compression Test
– Actuator Test
– Save & Upload Log
AGCO EDT Electronic Diagnostic 2025.09 Video Show:
AGCO EDT 2025 Electronic Diagnostic Tool Support Brands:
AGCO
Challenger
FENDT
FELLA
GLEANER
Laverda
Massey Ferguson
RoGator
ISEKI
SISU
SpraCoupe
Sunflower
TerraGator
Valtra
WHITE Planters
Some brands can not work
AGCO EDT 2025 Models Working:
2700E
9800_Windrower
AGCOMMAND_Generic
Agritalia
AL4EVO-Series
Amity Air Cart
ANT
Automation
AutoTill
Balers
BC4600
BE1035e
BX155
BX181
BX200
BX215
BX250
BX273
BX275
CEA MBus
CEA_BVSTractor
Centurion
Cerea
Delta
E-Link
FELLA_TP_911
FELLA_TS_12545
FELLA_TS_14055
Fendias
FE_X200_Engine
FE_X300_Engine
Gen2
Generic_System150
H2-16
Header_5300
HiPer AG Universal Support
IDEAL
IDEAL Automation
Iseki
IsekiMF1700
IsekiMF4600
LegacySteering
LegacySubSystemSteering
LelyHibiskus
LelyLW
LelyPT
LelyRP
LelyRP-F
LelyRPC
Lely_Legacy_Hardware
LRT
M200-Series
M300-Series
M400-Series
MF32
MF32SR
MF3700
MF9790
MF9790NA
MF9790_SA
MF_T5
Momentum
MT 789 C
MT 789D
MT 789E
M_PLUS
M_SeriesMY15
OPUS
Phase 2 Axial
Phase0
Planter
Planters_BR
R-Series
RG GP1
RG GP2
RG GP3
RG3
RG300 MY2019
RG300 MY2021
RG300 Series
RG600
RG600 GRV
RG600 MY2016
RG600 MY2016 GRV
RG600 MY2021
RG700
S1-18
S3 Phase 1 Axial
SA_TRACTOR
Series_M_StageV
SGR-1_Vehicle
Sserie
ST4
Sx7
Sx8
Sx9
T7
Tafe
TerraGator 8333 CVT
TG Legacy
TG T3 xx00
TG T3 xx03
TG T4 xx00
TG3
TG835
TG845
V2-21
V219T3
VB230
VG250
VT11
VT16
Windrower
Z12
Z15
Z16
Z2_Z3
Z9
AGCO EDT 2025 Plugin Working:
ACM
AG 150
AG 153
AGCOMMAND
C1000
C2100
C3000
CEATrans_MBus
CEA_Guide
EEM3
EEM4
EEM4F_Diagnostics
EEM4S5
EEM4_C63
EEM4_Final
EOL_Support_Tools
EXT_Audit
FPT
GFX750
HiPerAG
HuscoHydraulics
HVAC
Iseki_T4F
ISOBusCheck
Jax MT Lt Ptn
LCP
LHLink
MAN
MFA
Mitsubishi
NoracUC5
NT03
PVED_CL
SCM
SGR1
Shibaura
SimpsonT4F
TIM
Tractor Bus
ValtraArmrest
VarioGuide
X700_HB
X700_TB
AGCO EDT 2024 Update Release Notes:
Release Notes – 4/16/2025 – Update 2025.2
EDT NOTES:
EDT Version: 1.128.24284.909
Vehicles Affected:
Massey Ferguson: Square Balers: 2224, 2233, 2234, 2234XD, 2244
Fendt: Square Balers: 990, 1270, 1290, 1290XD, 12130
Vehicle Version:
1.34
Software:
EXT 01.12.00
Hide needle calibration when digital knotter position is enabled
Upgrade ITK libraries to 1.5.3
Fix problem when setting fieldname to empty widestring using certain terminals
Vehicles Affected:
Challenger: 660B made in Brazil, 670B made in Brazil, 680B made in Brazil
Massey Ferguson: 9695 made in Brazil, 9795 made in Brazil, 9895 made in Brazil
Valtra: BC6800, BC7800, BC8800
Vehicle Version:
1.34
Plug-Ins:
ACM plugin version 6.22
Vehicles Affected:
Massey Ferguson: MF 6700S Stage 5 Series
Massey Ferguson: MF 7700S Stage 5 Series
Vehicle Version:
3.20
General:
Fixed and issue that if the ACM hardware cannot be detected and the GW03 is selected, the
software version changes from the GW03 version to the GW04 version when the software
flash is started.
Software:
New NT03 Embedded Software V3.00.34 :
Bug fixing
New NT03 Standalone Software V3.00.34 :
Bug fixing
Vehicles Affected:
Massey Ferguson: 2700-4700 Series
Massey Ferguson: 6700R Series
Massey Ferguson: Global Series 4700-5700-6700
Valtra: A100
Valtra: A100Hitech Series
Valtra: A4, A4S
Valtra: A4Hitech Series
Valtra: AC52.5, AC54.5, AC56.5
Vehicle Version:
7.8
General:
Add Tier0 MF models everywhere Tier2 models were available, because of end of life of Tier2.
Software:
Add Tier0 engine software for MF
Vehicles Affected:
Fendt: Fendt tractor ACM support, X1000 Series
Vehicle Version:
1.26
Software:
Update ACM to ver 06.00.03. Wifi connection now supports encryption.
Plug-Ins:
Update ACM plugin to support Wifi encryption.
Vehicles Affected:
Fendt: Slicer 1010 KC PRO
Fendt: Slicer 1010 KCB
Release Notes – 8/27/2025 – Update 2025.4
EDT NOTES:
EDT Version: 1.128.25190.1121
Bug Fixes:
Enhancements:
Updated WinSCP to version 6.5.2
Minor improvements to diagnostic functionality.
Vehicles Affected:
Challenger: WR9900 Series
Massey Ferguson: WR9900 Series
Vehicle Version:
1.67
Software:
NT03 v5.00.17
Fix header float conversion between imperial and metric
Fix USB icon stays active when USB is removed
Fix secondary monitor freeze in some circumstances
Fix primary monitor crash when shifting into rear steer
Fix guidance overlap not being maintained in both directions
Fix not applying overlap after key switch but still showing right value
Vehicles Affected:
Massey Ferguson: Square Balers: 2224, 2233, 2234, 2234XD, 2244
Fendt: Square Balers: 990, 1270, 1290, 1290XD, 12130
Vehicle Version:
1.37
Diagnostics:
Add virtual CAN-Bus to monitor availability of ECUs while connected to ISOBUS connector.
Make backup of EEPROM before upgrading software
Configuration:
Add possibility to change electronic/mechanical knotter trip without an authorization key
Software:
EXT 01.14.01
Fix sending amount of cut bales to ACM and Infotrac at startup
Fix sending cutter override alarm when override is active and not only while button is pressed
Change delay for missing machine speed to 60 seconds to give ACM time to get started
Fix having active parking brake alarms after parking brake has been turned off
Fix displaying a double indicator when both load bullets are not sending values
Improve load bullet diagnostics
Fix having infobox items available for moisture system that was previously connected
Vehicles Affected:
Challenger: 660B made in Brazil, 670B made in Brazil, 680B made in Brazil
Massey Ferguson: 9695 made in Brazil, 9795 made in Brazil, 9895 made in Brazil
Valtra: BC6800, BC7800, BC8800
Vehicle Version:
1.36
Configuration:
The “internal error” no longer occurs when opening the Combine Setup configuration page.
Vehicles Affected:
Challenger: 520C
Challenger: 540C
Challenger: 560C
Massey Ferguson: 9595S
Massey Ferguson: 9695S
Massey Ferguson: 9795S
Massey Ferguson: 9895S
Valtra: 6800
Valtra: 7800
Vehicle Version:
1.62
General:
Software update for EMU and VMM, replacement of the MVEC with HCDM
Guidance System only AGS-2
Monitor only X35
Diagnostics:
Shaft Speeds: added block with active tailboard – spinners speed
Replaced all the relays of MVECs with HCDMs
Configuration:
Added 2 more options for discharge type: Chopper -active tailboard, straw spreader – Hyd
Software:
VMM ver. BB: 5.38 b63; LL: 0.66 b101
EMU ver. 6.6
Plug-Ins:
Removed AGCOCOMMAND, AG3000
Vehicles Affected:
Massey Ferguson: 2700-4700 Series
Massey Ferguson: 6700R Series
Massey Ferguson: Global Series 4700-5700-6700
Valtra: A100
Valtra: A100Hitech Series
Valtra: A4, A4S
Valtra: A4Hitech Series
Valtra: AC52.5, AC54.5, AC56.5
Vehicle Version:
8.0
Software:
New Dashboard Software v2.14 for Valtra
v2.14:
P24325 – Global Series non-RMI hectars counter not working
v2.13:
Add new logic for stationary mode of the PTO
v2.10:
Fix issue of engine hours that cannot be displayed higher than 6553 on dashboard
Support New DEF Gauge for T4F engine (New Choice in label code D = 4)
New Auto7 Transmission Software v2.33.0 for Valtra
v2.33.0:
P19661 – GS Harsh engagement with clutch pedal (Auto7)
P21541 – Power shuttle lever harsh
Bug Fix – PTO can disengage without error code due to false detection of Speed change
v2.27.0:
Compatible with new Auto7 Hardware
New Auto7 Linkage Software v1.39.0 for Valtra
v1.39.0:
Compatibility with new Auto7 Hardware
Finalize compatibility with New Bosch Rear Hitch valve
v1.34.0:
Improve PTO start performance to fix error code of energy disc
Improve external command management of rear hitch
Add new logic for stationary mode of the PTO (Need to be used with Dashboard software V2.13)
New Auto7 Cab ECU software v2.4.3 for Valtra
Added new appl version with latest kernel
Vehicles Affected:
Lely: Pro and Control
Vehicle Version:
0.6
General:
Additional note in the E-LINK Pro Terminal model to distinguish between version 1 and 2, since a software update is only provided for version 1.
Vehicles Affected:
Fendt: Slicer 1010 KC PRO
Fendt: Slicer 1010 KCB
Fendt: Slicer 1010 RC PRO
Fendt: Slicer 1010 RCB
Fendt: Slicer 960 KC PRO
Fendt: Slicer 960 KCB
Fendt: Slicer 960 RC PRO
Fendt: Slicer 960 RCB
Massey Ferguson: DM 10114 TL-KC PRO
Massey Ferguson: DM 10114 TL-KCB
Massey Ferguson: DM 10114 TL-RC PRO
Massey Ferguson: DM 10114 TL-RCB
Massey Ferguson: DM 9614 TL-KC PRO
Massey Ferguson: DM 9614 TL-KCB
Massey Ferguson: DM 9614 TL-RC PRO
Massey Ferguson: DM 9614 TL-RCB
Vehicle Version:
1.4
General:
New in SW 1.3.0:
Softkey integration
Rework Alarm concept (belts not always off)
Support of imperial unit system
Disable automatic rear light control when driving reverse
Software:
SW 1.3.0
Vehicles Affected:
Fella: TS 12545 PRO
Fendt: Former 12545 PRO
Massey Ferguson: RK 1254 TRC-PRO
Vehicle Version:
4.0
General:
New in SW 4.0.0:
new UI
Softkeys integration for terminal “Smart570”
Support of imperial unit system (US market)
manual transport: reuse arm position sensor (if ok) to switch off arm down output below 50%. If sensor not ok: show warning.
show warning for front rakes down in manual transport
Stop SK: switch to manual transport, also in alarm
manual working: show pop up also after alarm
manual working: add pop up to confirm working/headland position
emergency stop (case differentiation)
working lights mid and rear in transport position on (2x front off)
reduce scheduler timings for rake, chassis and automatism wrapper to handle Control Loop behavior to stop when target is reached
Software:
SW 4.0.0
Vehicles Affected:
Fella: TS 14055 PRO
Fendt: Former 14055 PRO
Massey Ferguson: RK 1404 TRC-PRO
Vehicle Version:
5.3
General:
New in SW 5.2.0:
reduce scheduler timings for rake, chassis and automatism wrapper to handle Control Loop behavior to stop when target is reached
working lights mid and rear in transport position on (2x front off)
emergency stop (case differentiation)
Softkeys integration for terminal “Smart570”
Support of imperial unit system (US market)
manual transport: reuse arm position sensor (if ok) to switch off arm down output below 50%. If sensor not ok: show warning.
show warning for front rakes down in manual transport
Stop SK: switch to manual transport, also in alarm
manual working: show pop up also after alarm
manual working: add pop up to confirm working/headland position
New in SW 4.6.0:
reduce scheduler timings for rake, chassis and automatism wrapper to handle Control Loop behavior to stop when target is reached
New in SW 3.7.0:
reduce scheduler timings for rake, chassis and automatism wrapper to handle Control Loop behavior to stop when target is reached
Software:
MY 2025- SW 5.2.0
MY -2023 SW 4.6.0
MY -2018 SW 3.7.0
Vehicles Affected:
Fendt: Former 1000 C PRO
Fendt: Former 920 C PRO
Fendt: Former 860 C PRO
Massey Ferguson: RK 1002 TRC-PRO Gen2
Massey Ferguson: RK 922 TRC-PRO Gen2
Massey Ferguson: RK 862 TRC-PRO Gen2
Vehicle Version:
1.4
General:
New in SW 1.3.0:
softkeys Integration for terminal “Smart570”
Support of imperial unit system (US market)
manual working: show pop up also after alarm
manual working: add pop up to confirm working/headland position
emergency stop (case differentiation)
Bugfix: Velocity warning in transport mode
Bugfix: Area counter calculation
reduce scheduler timings for rake, chassis and automatism wrapper to handle Control Loop behavior to stop when target is reached behavior to stop when target is reached
Software:
SW 1.3.0
Vehicles Affected:
Massey Ferguson: 1E.35, 1M.35
Vehicle Version:
2.43
Software:
New engine software with modified fuel mappings to solve a severe engine flutter issue.
Diagnostic Trouble Codes:
Description for DTC 174.3 changed to “Fuel temperature sensor voltage above normal or open circuit”
Vehicles Affected:
Massey Ferguson: 7342
Massey Ferguson: 7342 MCS
Massey Ferguson: 7343
Massey Ferguson: 7343 MCS
Massey Ferguson: 7344
Massey Ferguson: 7344 MCS
Fendt: Corus 518
Fendt: Corus 518 MCS
Fendt: Corus 522
Fendt: Corus 522 MCS
Fendt: Corus 526
Fendt: Corus 526 MCS
Vehicle Version:
6.29
General:
General calibration changes for all engine variants
Improved DPF service/maintenance information, SPN 3701, FMI 14, Particulate filter: Service required, ash level too high. New DPF ash model is utilized
Activated engine tests via diagnostic tool/tester: High pressure pump delivery rate test and Rail Pressure Control Valve (PCV) test
Software:
Engine spec.49806 file ACX293487D_1.hex.gz
Engine spec.74808 file ACX294581D_1.hex.gz
Engine spec.74809 file ACX294580D_1.hex.gz
Plug-Ins:
added EEM4F_Diag ver. 6.23
Vehicles Affected:
Massey Ferguson: MF 3700 Series
Massey Ferguson: MF 3X Series
Vehicle Version:
1.91
Software:
New TCU software V2.1 for MF3 models only:
Compatibility with new Husco Control Valve
Remove sporadic appearance of E095, E098 and E101 errors
Vehicles Affected:
Fendt: Opus B3 Terminal
Massey Ferguson: Opus B3 Terminal
Vehicle Version:
0.2
Software:
Add bootloader update package
Vehicles Affected:
Challenger: 520C, 530C, 540C, 540E, 550C, 560C, 560E
Fendt: 9390R, 9450R, 9480R
Massey Ferguson: 9520, 9530, 9540, 9545, 9550, 9560, 9565
Vehicle Version:
4.58
General:
Bugfix: VMM6 does not update.
Vehicles Affected:
Massey Ferguson: 530R
Massey Ferguson: 535R
Valtra: R530
Valtra: R535
Vehicle Version:
2.4
Software:
NT01 (L32 – V32.00.00)
Support for old & new VD0X hardware
Guidance overlap saved after key cycle
Ukrainian translations added
Raven RS1 (v25.1.5.12)
DEFECT RESOLUTION
Slingshot pool load fix
Raven RCM-S (v25.1.1.8)
NEW FEATURES
Added Y Drop Fertilizer Features
Added Tiered On/OFF mode
ENHANCEMENTS
Default bypass stabilization feature to on to improve rate stability while in bypass mode
See Stability Enhancer option on User Settings page below
Add Valve Delay feature in Bypass mode
Added additional nozzles to 90, 100, and 120 ft AGCO booms
Added VRA min/max window masks
Added Tiered On/Off Tier Widget
Improved Tiered On/Off Control for smoother transitions between tiers
Enabled Product Setup page
Added Default Rates, Pressures, Pressure alarm, and Bypass only deadband valve control to 2%
BUG FIXES
Fixed AGCO machine profile Auto selection
NCV Software release notes
ENHANCEMENTS
Improved CAN passthrough latency
Reduced CAN traffic by reducing traffic when NCV states are commanded on/off rapidly
Added checks for logic temperature range exceeding maximum values
Added support for NCV Aux state mismatch alarm for KZ valves
Display nozzle current as 0 A when coil not energized on the NCV2 Diagnostics page
Raven XRT ABM (v25.3.0.13)
NEW FEATURES
42m boom profile added for R5
Raven ICD Chem Injection (v25.1.0.3)
ENHANCEMENTS
Default “Pair with Raven Controller Only” checkbox setting to ON
Added a Service Menu to the Tests dropdown menu.
Fixed issue with catch test calculation of Flow Correction %
Suppressed alarms during diagnostic tests
Added support for Product Identification PGN and updated ECU ID PGN to add a field for Hardware version
Fixed rounding issues on volumes sent via ISOBUS to the product controllers
Guidance Controller (VD0X) (v3.247)
Changes since v3.245 (multiple changes from v3.198-v3.245)
AUTO-5034 – Update receiver firmware check for upcoming versions
AUTO-5116 – Integration of steering status in the NMEA2000 message PGN 1F903h
BUG-11533 – Internal 450 MHz Trimble Modem not detected
BUG-15338 – UDS-Service inject_gnss_authorization not working correctly
Novatel Smart7 GNSS (vES7PR0901RN0000)
Compatible with VD0X v3.247
Trimble AG482 GNSS (v12.40.003.4)
Compatible with VD0X v3.247
Plug-Ins:
CEA Guide version 8.35
Bug-fixes:
BUG-10021 – Component Info and Electrical Diagram links are not working
BUG-11337 – EDT Looks For “RG3 Chassis EXT VIN” Auth Code When Attempting EXT VIN Change on TG3 Machine
Vehicles Affected:
Fendt: RG645, RG655, RG665 MY2023
Vehicle Version:
1.7
General:
improved update flash
new sprayer software
new Altek bridge software
new ACM software
Software:
Sprayer software: AGCO_RG600P-I_01.06.00
Altek bridge software: 1.0.4
Plug-Ins:
ACM software: 05.03.02
Vehicles Affected:
Fendt: Rogator 600 MY2024
Vehicle Version:
1.5
General:
Improved sprayer software update
new sprayer software
new Altek bridge software
new ACM software
Software:
Sprayer software: AGCO_RG600P-I_01.06.00
Altek bridge software: 1.0.4.
Plug-Ins:
ACM software: 05.03.02
Vehicles Affected:
Fendt: Rogator 600 MY2025
Vehicle Version:
1.2
General:
Improved sprayer software flash
new sprayer software
new Altek bridge software
new ACM software
Software:
Sprayer software: AGCO_RG600P-I_01.06.00
Altek bridge software: 1.0.4
Plug-Ins:
ACM software: 05.03.02
Vehicles Affected:
Massey Ferguson: 2700
Vehicle Version:
1.0
Diagnostics:
Simpson engine diagnostics
Vehicles Affected:
Fendt: 5255 L, 5255 L PL, 6275 L, 6275 L PL, 5275 C, 5275 C SL 5275 C PL, 5275 C PLI, 6335 C, 6335 C PL, 6335 C PLI
Laverda: M 300, M 300 LC, M310, M310 LC, M 400, M 400 LC, M 400 LCI, M410, M410 LC, M410 LCI
Massey Ferguson: 7345 S, 7345 S PL, 7347 S, 7347 S PL, 7360, 7360PL, 7360 PLI, 7370, 7370 PL, 7370 PLI, 7360 AL 4
Vehicle Version:
0.92
General:
General calibration changes for all engine variants
Improved DPF service/maintenance information, SPN 3701, FMI 14, Particulate filter: Service required, ash level too high. New DPF ash model is utilized
Activated engine tests via diagnostic tool/tester: High pressure pump delivery rate test and Rail Pressure Control Valve (PCV) test
Software:
Engine spec.74809 file ACX294580D_1.hex.gz
Engine spec.74810 file ACX294579D_1.hex.gz
Engine spec.84805 file ACX293935D_2.hex.gz
Engine spec.74873 file ACX295086D_1.hex.gz
Engine spec.84722 file ACX257102A_1.hex.gz
Vehicles Affected:
Fendt: Standalone NT03 Terminal for Implements
Massey Ferguson: Standalone NT03 Terminal for Implements
Vehicle Version:
0.2
Software:
Add latest SW 04.001.02
support Korean, Japanese and Greek languages
DCU VT stack integrated (old was VT stack from NT01)
Vehicles Affected:
Gleaner: T61, T71, T81
Vehicle Version:
1.8
General:
MFA joystick sensitivity improved
Software:
MFA EEPROM ver. 61725
Vehicles Affected:
Valtra: BH G4, BH214 Hitech, BH224 Hitech, M5 Series
Massey: MF7300, MF 6M
Vehicle Version:
3.29
General:
M5 Series, MF 6M**- EDT 2025.4 Test Mode Only**
Added SW package SER2025.1 RP1;
Added Power shuttle Diagnostic by function for MF;
Added Feature unlock;
Added engine spec number;
Fixed Transmission Controller parameters;
Fixed Label codes configuration
BH G4, BH214 Hitech, BH224 Hitech, MF7300
Bugfix: Graphical Diagnostics – I/O Tests – Internal Error – Missing Line on position 68
Vehicles Affected:
Valtra: T4-series 1A7 / 1B8, N4-series 1B7 / 1C8
Vehicle Version:
1.111
Plug-Ins:
Change the instructions for resetting the PVED_CL valve from “Turn ignition key OFF. Wait 3 seconds and turn ignition key ON again.” to “Press the button to turn off the guidance, wait 3 seconds, and press it again to turn it back on.”
Vehicles Affected:
Massey Ferguson: 197, 235, 265
Vehicle Version:
1.48
General:
This update requires that the guidance receiver is updated to the latest software version.
Specifically for units with Trimble receivers, if after the software updates the system is not recognized on the monitor or the only correction source available is Autonomous, then technicians will need to clear the BB Ram to allow the receiver to do a full reboot. To do this the technicians will need to download the Trimble Toolbox+ app onto their mobile device. From there use the following steps to navigate to the appropriate location within the app:
Turn on the receiver.
Connect the Trimble Toolbox+ app with the receiver.
Run the AgRemote utility.
Navigate to the Clear BB RAM screen.
Press double window icon until “Yes” appears.
Press enter.
Diagnostics:
Add header down valve to valve manifold diagnostics screen
Software:
Ground Drive v04.006.00 and v05.004.00
Fix to resolve multiple press on handle to engage guidance.
Fix charge pressure reading to match engine reading
NT03 v5.00.17
Fix header float conversion between imperial and metric
Fix USB icon stays active when USB is removed
Fix secondary monitor freeze in some circumstances
Fix primary monitor crash when shifting into rear steer
Fix guidance overlap not being maintained in both directions
Fix not applying overlap after key switch but still showing right value
VD04 VD0X.GLB001.I.03.198.
Improved pivot recording algorithm
Vehicles Affected:
Challenger: MT400E Series
Challenger: MT500E Series
Iseki: i5700 Series
Iseki: i6700 Series
Iseki: i7700 Series
Massey Ferguson: 5700S Series
Massey Ferguson: 5700SL Series
Massey Ferguson: 6700S Series
Massey Ferguson: 7700 Made in Brazil Series
Massey Ferguson: 7700 Series
Massey Ferguson: 7700S Series
Valtra: T195-250 Series
Vehicle Version:
8.43
Bug-fix:
BUG-21955 – SAM16 Only – Wrong image tutorial for Can-BOX connection in Engine Diagnostic
Release Notes – 6/30/2025 – Update 2025.3.OC1
EDT NOTES:
EDT Version: 1.128.24284.909
Vehicles Affected:
Fendt: 932, 934, 934H, 937, 937H, 937H HT
Vehicle Version:
1.26
Software:
Chassis Controller EXT (v03.04.08):
BUG-20922(PPRP29248) Boom Tilt logic getting stuck on when missing MFA messages
Sedi hussein –
I tested this product and it works great, but the only downside is that it doesn’t cover all brands models.